70-00144-01-01 Proprietary Redline Communications © 2011 Page 38 of 52 March 9, 2011
4.5.4 Install Indoor PoE Power Adapter
The indoor Power-over-Ethernet (PoE) power adapter provides operational power and
the Ethernet connection to the RDL-2000. The PoE is auto-sensing 110-240 VAC. A
grounded AC outlet must be provided within about one meter of the PoE adapter
mounting location. The AC power cable is supplied with a grounding power plug. Do not
defeat this important safety feature.
The indoor end of the Redline supplied Ethernet cable is terminated with a non-hooded
RJ-45 connector. This connects to the OUTPUT (DATA & POWER) port of the indoor
PoE power adapter. The minimum diameter conduit or hole required is 18 mm (11/16 in).
The power block provides two Ethernet interfaces:
INPUT (DATA): Connection to local network equipment.
OUTPUT (DATA & POWER): Signal and power to the RDL-2000.
Customer equipment including personal computers, routers, etc., must be connected
only to the INPUT (DATA) port on the PoE unit. Only the outdoors Ethernet interface
cable connecting to the RDL-2000 can be safely connected to the OUTPUT (DATA &
the OUTPUT (DATA & POWER) connector on the Power-over-
adapter may damage customer equipment.